Fault code E02 on Hermann units (Micraplus, Micracom Condens, Supermicra, Habitat) indicates: Overtemperature limit thermostat trip. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Hermann E02)

Manufacturer / BrandHermann
Error CodeE02
System / CategoryBoilers & Heating
Compatible ModelsMicraplus, Micracom Condens, Supermicra, Habitat
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsSafety thermostat: 0 Ω when cold

2. Guided Symptom Troubleshooting Matrix

🔎 Is the circulator pump burning while the radiators are still cold?
✓ Scenario A: Yes (Confirmed)

Unlock the circulator pump shaft by removing the front threaded plug.

✕ Scenario B: No (Not Present)

Clogged exchanger or faulty limit thermostat.

3. Step-by-Step Multimeter Testing Procedure (E02)

  1. Safety Power Isolation: Disconnect the Hermann unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E02 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Safety thermostat: 0 Ω when cold.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Hermann Error E02

🔄 Hermann E02 Reset: Wait 10 minutes for it to cool and press 'Reset'.
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Hermann Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Hermann E02?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Hermann Error Code E02

What does Hermann error code E02 mean?

Hermann E02: Overtemperature limit thermostat trip (Micraplus, Micracom Condens, Supermicra, Habitat). Multimeter Specs: Safety thermostat: 0 Ω when cold.

How do I reset Hermann fault code E02?

Wait 10 minutes for it to cool and press 'Reset'.

What multimeter values should I check for Hermann code E02?

Safety thermostat: 0 Ω when cold