Hayward Error Code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Hayward Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell))
| Manufacturer / Brand | Hayward |
|---|---|
| Error Code | Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell) |
| System / Category | Pools & Lawn Mowers |
| Compatible Models | Cloradores Salinos and Equipos Hayward (AquaRite, AquaRite +, AquaRite Flo Advanced, Salt & Swim, Pump Max-Flo / Super Pump) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Star replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A) |
2. Guided Symptom Troubleshooting Matrix
Two very famous **Hayward AquaRite** breakdowns: 1) **If the screen is off or shows `0000` as soon as you start up**: in the upper right corner of the green electronic board of the AquaRite there is a **large black lentil the size of a β¬2 coin (it is the 2 Ξ© NTC Current Limiter / Thermistor `SL32 2R025`)**. With heat it splits in half and stops passing current to the cell; That black lentil costs **β¬4 on Amazon** and by soldering it in 5 minutes in the two holes of the plate you revive a β¬900 chlorinator! 2) **If it marks half salt (1,400 ppm)**: the **TurboCell (`T-Cell-3 / T-Cell-9 / T-Cell-15`)** cell has lime or has exhausted one of its two sides. **How ββto clear the fixed 'Inspect Cell' prompt (which occurs every 500 clock hours)**: Press and hold the small diagnostic button next to the screen for **3 seconds**.
Visually check the black bead (Thermistor SL32 2R025) on the AquaRite plate for cracks and clean the TurboCell.
3. Step-by-Step Multimeter Testing Procedure (Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell))
- Safety Power Isolation: Disconnect the Hayward unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Star replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Hayward Error Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)
Check OEM & aftermarket availability for Hayward NTC Temperature Sensor:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Hayward Error Code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)
What does Hayward error code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell) mean?
Hayward Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell): The Hayward AquaRite chlorinator display shows half the actual salt (e.g. 1,500 ppm instead of 3,200 ppm) and turns on 'Check Salt + Inspect Cell' (Cloradores Salinos and Equipos Hayward (AquaRite, AquaRite +, AquaRite Flo Advanced, Salt & Swim, Pump Max-Flo / Super Pump)). Multimeter Specs: Star replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A).
How do I reset Hayward fault code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)?
Press and hold the diagnostic button for 3 seconds to clear 'Inspect Cell'; check the black SL32 2R025 thermistor on the board or replace the T-Cell.
What multimeter values should I check for Hayward code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)?
Star replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A)