Hayward Error Code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell): Meaning, Multimeter Diagnosis & Fix

Fault code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell) on Hayward units (Cloradores Salinos and Equipos Hayward (AquaRite, AquaRite +, AquaRite Flo Advanced, Salt & Swim, Pump Max-Flo / Super Pump)) indicates: The Hayward AquaRite chlorinator display shows half the actual salt (e.g. 1,500 ppm instead of 3,200 ppm) and turns on 'Check Salt + Inspect Cell'. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Pools & Lawn Mowers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Hayward Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell))

Manufacturer / BrandHayward
Error CodeLectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)
System / CategoryPools & Lawn Mowers
Compatible ModelsCloradores Salinos and Equipos Hayward (AquaRite, AquaRite +, AquaRite Flo Advanced, Salt & Swim, Pump Max-Flo / Super Pump)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsStar replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does your Hayward AquaRite chlorinator turn off saying 'Check Salt' even though the water is well salted (or does the screen turn off entirely but there is power)?
βœ“ Scenario A: Yes (Confirmed)

Two very famous **Hayward AquaRite** breakdowns: 1) **If the screen is off or shows `0000` as soon as you start up**: in the upper right corner of the green electronic board of the AquaRite there is a **large black lentil the size of a €2 coin (it is the 2 Ξ© NTC Current Limiter / Thermistor `SL32 2R025`)**. With heat it splits in half and stops passing current to the cell; That black lentil costs **€4 on Amazon** and by soldering it in 5 minutes in the two holes of the plate you revive a €900 chlorinator! 2) **If it marks half salt (1,400 ppm)**: the **TurboCell (`T-Cell-3 / T-Cell-9 / T-Cell-15`)** cell has lime or has exhausted one of its two sides. **How ​​to clear the fixed 'Inspect Cell' prompt (which occurs every 500 clock hours)**: Press and hold the small diagnostic button next to the screen for **3 seconds**.

βœ• Scenario B: No (Not Present)

Visually check the black bead (Thermistor SL32 2R025) on the AquaRite plate for cracks and clean the TurboCell.

3. Step-by-Step Multimeter Testing Procedure (Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell))

  1. Safety Power Isolation: Disconnect the Hayward unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Star replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Hayward Error Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)

πŸ”„ Hayward Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell) Reset: Press and hold the diagnostic button for 3 seconds to clear 'Inspect Cell'; check the black SL32 2R025 thermistor on the board or replace the T-Cell.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Hayward NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Hayward Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Hayward Error Code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)

What does Hayward error code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell) mean?

Hayward Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell): The Hayward AquaRite chlorinator display shows half the actual salt (e.g. 1,500 ppm instead of 3,200 ppm) and turns on 'Check Salt + Inspect Cell' (Cloradores Salinos and Equipos Hayward (AquaRite, AquaRite +, AquaRite Flo Advanced, Salt & Swim, Pump Max-Flo / Super Pump)). Multimeter Specs: Star replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A).

How do I reset Hayward fault code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)?

Press and hold the diagnostic button for 3 seconds to clear 'Inspect Cell'; check the black SL32 2R025 thermistor on the board or replace the T-Cell.

What multimeter values should I check for Hayward code Lectura of Sal Muy Baja e 'Inspect Cell' (Termistor / Célula T-Cell)?

Star replacement Hayward AquaRite board: Inrush NTC SL32 2R025 current limiting thermistor (2 Ohms 25A)