Engineering Review: 2026-11-21 · SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Refrigerators & Freezers Medium Severity · Protection Mode

Haier (Refrigerators) Error Code F1 / F2 / E1: Meaning, Multimeter Diagnosis & Fix

Fault code F1 / F2 / E1 on Haier (Refrigerators) units (Refrigerators Combi, Multi-Door (Cube 83/90) and Side by Side Haier (HTR, HB18, HTW, HSR, C3FE)) indicates: Fault in the refrigerator compartment temperature NTC sensor (F1), room sensor (F2) or evaporator fan (E1). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Refrigerators & Freezers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Haier (Refrigerators) F1 / F2 / E1)

Manufacturer / BrandHaier (Refrigerators)
Error CodeF1 / F2 / E1
System / CategoryRefrigerators & Freezers
Compatible ModelsRefrigerators Combi, Multi-Door (Cube 83/90) and Side by Side Haier (HTR, HB18, HTW, HSR, C3FE)
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsHaier NTC probes at 25°C: 5 kΩ or 10 kΩ depending on series

2. Guided Symptom Troubleshooting Matrix

🔎 Does the Haier refrigerator door touch panel display F1, F2 or E1?
✓ Scenario A: Yes (Confirmed)

1) If you open and close the door a lot on a model with a screen on the door and a code flashes or the screen turns off when you open the door: **the cables that pass inside the upper hinge of the door** have been cut from opening and closing so much (remove the plastic cover from the upper hinge and splice the broken cable with a soldering iron and heat shrink). 2) If it is **E1**: the freezer interior fan is slowed by ice.

✕ Scenario B: No (Not Present)

Check the wiring harness in the upper door hinge grommet before changing probes.

3. Step-by-Step Multimeter Testing Procedure (F1 / F2 / E1)

  1. Safety Power Isolation: Disconnect the Haier (Refrigerators) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault F1 / F2 / E1 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Haier NTC probes at 25°C: 5 kΩ or 10 kΩ depending on series.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Haier (Refrigerators) Error F1 / F2 / E1

🔄 Haier (Refrigerators) F1 / F2 / E1 Reset: Check continuity of the wiring harness on the upper door hinge and defrost for 24 hours if the fan rubs against ice (E1).
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Haier NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Haier (Refrigerators) F1 / F2 / E1?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Haier (Refrigerators) Error Code F1 / F2 / E1

What does Haier (Refrigerators) error code F1 / F2 / E1 mean?

Haier (Refrigerators) F1 / F2 / E1: Fault in the refrigerator compartment temperature NTC sensor (F1), room sensor (F2) or evaporator fan (E1) (Refrigerators Combi, Multi-Door (Cube 83/90) and Side by Side Haier (HTR, HB18, HTW, HSR, C3FE)). Multimeter Specs: Haier NTC probes at 25°C: 5 kΩ or 10 kΩ depending on series.

How do I reset Haier (Refrigerators) fault code F1 / F2 / E1?

Check continuity of the wiring harness on the upper door hinge and defrost for 24 hours if the fan rubs against ice (E1).

What multimeter values should I check for Haier (Refrigerators) code F1 / F2 / E1?

Haier NTC probes at 25°C: 5 kΩ or 10 kΩ depending on series