Ferroli Error Code A06: Meaning, Multimeter Diagnosis & Fix

Fault code A06 on Ferroli units (Bluehelix, Domiproject, Domicompact, Divatech) indicates: Repeated loss of flame after the ignition phase. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Ferroli A06)

Manufacturer / BrandFerroli
Error CodeA06
System / CategoryBoilers & Heating
Compatible ModelsBluehelix, Domiproject, Domicompact, Divatech
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsMinimum pressure in burner: > 2.0 mbar

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does A06 come out after the flame tries to hold several times in 4 minutes?
βœ“ Scenario A: Yes (Confirmed)

Poor chimney draft (smoke recirculation) or unstable gas pressure in the ramp.

βœ• Scenario B: No (Not Present)

Minimum ignition power parameter too low.

3. Step-by-Step Multimeter Testing Procedure (A06)

  1. Safety Power Isolation: Disconnect the Ferroli unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault A06 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Minimum pressure in burner: > 2.0 mbar.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Ferroli Error A06

πŸ”„ Ferroli A06 Reset: Press the 'Reset' button.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Ignition & Flame Electrode)?

Check OEM & aftermarket availability for Ferroli Ignition & Flame Electrode:

Want to use the interactive diagnostic wizard or electrical calculators for Ferroli A06?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Ferroli Error Code A06

What does Ferroli error code A06 mean?

Ferroli A06: Repeated loss of flame after the ignition phase (Bluehelix, Domiproject, Domicompact, Divatech). Multimeter Specs: Minimum pressure in burner: > 2.0 mbar.

How do I reset Ferroli fault code A06?

Press the 'Reset' button.

What multimeter values should I check for Ferroli code A06?

Minimum pressure in burner: > 2.0 mbar