Ecoforest Error Code Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Ecoforest Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch))
| Manufacturer / Brand | Ecoforest |
|---|---|
| Error Code | Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch) |
| System / Category | Boilers & Heating |
| Compatible Models | Estufas e Hidroestufas of Pellets Españolas Ecoforest (Vigo, Venus, Tokio, Cantina, Atenas, Hidrocopper - CPU Electrónica Propia) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | In Ecoforest stoves, if the rear overtemperature thermostat trips (black/red button behind the stove), it is also reflected by cutting the safety series |
2. Guided Symptom Troubleshooting Matrix
In all **Ecoforest** stoves, the safety circuit joins in series the **vacuum switch (air pressure switch)** and the **hopper and water safety thermostats**: 1) Thoroughly clean the **lower ashtray drawer and the smoke passages behind the hearth plate** (in the Ecoforest Vigo/Venus you must lift the upper plate and pass the tube scraper rod daily, and vacuum the gap under the ashtray removing the wing nuts every 500 kg). 2) Open the side cover, release the **silicone tube from the round vacuum switch** and blow towards the metal side of the stove (not towards the vacuum switch) to unclog the spout that enters the smoke chamber.
To clear the alarm in Ecoforest: press the **On/Off (hand / circle)** button once the ash jam has been resolved.
3. Step-by-Step Multimeter Testing Procedure (Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch))
- Safety Power Isolation: Disconnect the Ecoforest unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: In Ecoforest stoves, if the rear overtemperature thermostat trips (black/red button behind the stove), it is also reflected by cutting the safety series.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Ecoforest Error Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch)
Check OEM & aftermarket availability for Ecoforest Pressure Switch:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Ecoforest Error Code Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch)
What does Ecoforest error code Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch) mean?
Ecoforest Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch): 'Alarm 1: Depression Failure / Door Open' flashes on the screen of your Ecoforest stove and stops the bone/pellet falling. (Estufas e Hidroestufas of Pellets Españolas Ecoforest (Vigo, Venus, Tokio, Cantina, Atenas, Hidrocopper - CPU Electrónica Propia)). Multimeter Specs: In Ecoforest stoves, if the rear overtemperature thermostat trips (black/red button behind the stove), it is also reflected by cutting the safety series.
How do I reset Ecoforest fault code Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch)?
Vacuum the lower ducts of the exchanger and the chimney register, unclog the vacuum switch tube intake and press the off button to reset.
What multimeter values should I check for Ecoforest code Alarma 1 / Fault / Failure Depresión (Door / Chimenea / pressure switch)?
In Ecoforest stoves, if the rear overtemperature thermostat trips (black/red button behind the stove), it is also reflected by cutting the safety series