Boilers & Heating High Severity · Safety Lockout

De Dietrich Error Code E01 / E02: Meaning, Multimeter Diagnosis & Fix

Fault code E01 / E02 on De Dietrich units (Boilers of Condensación of Dietrich (Naneo, Evodens, Modulens, Zena, Vivadens)) indicates: Lockout / Blockage due to ignition failure lockout without flame sensing circuit (E01) or falsa Flame parasitaria (E02) in of Dietrich. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Boilers & Heating subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (De Dietrich E01 / E02)

Manufacturer / BrandDe Dietrich
Error CodeE01 / E02
System / CategoryBoilers & Heating
Compatible ModelsBoilers of Condensación of Dietrich (Naneo, Evodens, Modulens, Zena, Vivadens)
Severity LevelHigh Severity · Safety Lockout
Multimeter Specsvoltage Maximum admisible Neutro-Tierra: < 2.0V AC

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does De Dietrich error code E01 / E02 return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Lockout / Blockage due to ignition failure lockout without flame sensing circuit (E01) or falsa Flame parasitaria (E02) in of Dietrich). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: voltage Maximum admisible Neutro-Tierra: < 2.0V AC. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: inspect suministro of gas and Polarity Fase/Neutro; Press and hold 'Reset' For / During 3 seconds.

3. Step-by-Step Multimeter Testing Procedure (E01 / E02)

  1. Safety Power Isolation: Disconnect the De Dietrich unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E01 / E02 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: voltage Maximum admisible Neutro-Tierra: < 2.0V AC.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear De Dietrich Error E01 / E02

πŸ”„ De Dietrich E01 / E02 Reset: inspect suministro of gas and Polarity Fase/Neutro; Press and hold 'Reset' For / During 3 seconds.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Ignition & Flame Electrode)?

Check OEM & aftermarket availability for De Dietrich Ignition & Flame Electrode:

Want to use the interactive diagnostic wizard or electrical calculators for De Dietrich E01 / E02?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: De Dietrich Error Code E01 / E02

What does De Dietrich error code E01 / E02 mean?

De Dietrich E01 / E02: Lockout / Blockage due to ignition failure lockout without flame sensing circuit (E01) or falsa Flame parasitaria (E02) in of Dietrich (Boilers of Condensación of Dietrich (Naneo, Evodens, Modulens, Zena, Vivadens)). Multimeter Specs: voltage Maximum admisible Neutro-Tierra: < 2.0V AC.

How do I reset De Dietrich fault code E01 / E02?

inspect suministro of gas and Polarity Fase/Neutro; Press and hold 'Reset' For / During 3 seconds.

What multimeter values should I check for De Dietrich code E01 / E02?

voltage Maximum admisible Neutro-Tierra: < 2.0V AC