Cointra Calentadores Error Code E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Cointra Calentadores E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme))
| Manufacturer / Brand | Cointra Calentadores |
|---|---|
| Error Code | E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme) |
| System / Category | Boilers & Heating |
| Compatible Models | Calentadores of Gas Cointra (Supreme 11/14 E, CETI, CPE-T, CobB, Optima, Godesia, MicroTop - Estancos and Atmosféricos) |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Correct spark plug separation from the burner in Cointra: 3.5 to 4.5 mm |
2. Guided Symptom Troubleshooting Matrix
In thermostatic heaters **Cointra Supreme / CPE**: **E1 = Absence of flame at ignition**: 1) Check that there is gas (if it is from a butane cylinder, when it is very cold the cylinder has no pressure or the regulator is blocked). 2) If you see through the sight glass that the flame does light up for 3 seconds and cuts off by marking **E1**: clean the tip of the **flame detector electrode** or check the wall plug to make sure there is no residual voltage between Neutral and Ground. **For E2**: false flame detected before opening the gas valve (moisture in the ionization plug).
Turn off the hot water tap, press the **On/Reset** button on the touch screen and turn the tap on again.
3. Step-by-Step Multimeter Testing Procedure (E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme))
- Safety Power Isolation: Disconnect the Cointra Calentadores unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Correct spark plug separation from the burner in Cointra: 3.5 to 4.5 mm.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Cointra Calentadores Error E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme)
Check OEM & aftermarket availability for Cointra Calentadores Ignition & Flame Electrode:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Cointra Calentadores Error Code E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme)
What does Cointra Calentadores error code E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme) mean?
Cointra Calentadores E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme): 'E1' or 'E2' appears on the touch screen of the Cointra Supreme / CETI watertight heater when you open the hot water tap (Calentadores of Gas Cointra (Supreme 11/14 E, CETI, CPE-T, CobB, Optima, Godesia, MicroTop - Estancos and Atmosféricos)). Multimeter Specs: Correct spark plug separation from the burner in Cointra: 3.5 to 4.5 mm.
How do I reset Cointra Calentadores fault code E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme)?
Check gas supply, clean the ionization electrode and press the power button on the screen to clear E1.
What multimeter values should I check for Cointra Calentadores code E1 / E2 (Fault / Failure ignition or flame sensing circuit in Cointra Supreme)?
Correct spark plug separation from the burner in Cointra: 3.5 to 4.5 mm