Clorador Salino (AstralPool / Zodiac / Hayward) Error Code No Flow / Flujo / FL1: Meaning, Multimeter Diagnosis & Fix

Fault code No Flow / Flujo / FL1 on Clorador Salino (AstralPool / Zodiac / Hayward) units (Cloradores Salinos AstralPool (Sel Clear, Smart Next, Elite), Zodiac (Ei2, eXO iQ), Sugar Valley (Aquascenic / Oxilife) and Hayward Aquarite) indicates: Alarm for lack of water flow ('No Flow' / 'Flow' / red flow LED) with the purifier pump on. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Pools & Lawn Mowers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Clorador Salino (AstralPool / Zodiac / Hayward) No Flow / Flujo / FL1)

Manufacturer / BrandClorador Salino (AstralPool / Zodiac / Hayward)
Error CodeNo Flow / Flujo / FL1
System / CategoryPools & Lawn Mowers
Compatible ModelsCloradores Salinos AstralPool (Sel Clear, Smart Next, Elite), Zodiac (Ei2, eXO iQ), Sugar Valley (Aquascenic / Oxilife) and Hayward Aquarite
Severity LevelLow Severity · Maintenance Advisory
Multimeter SpecsThe upper gas sensor of the cell makes contact through the water itself with the titanium body

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Is the pool pump running but the salt chlorinator stops marking 'No Flow'?
βœ“ Scenario A: Yes (Confirmed)

For safety so that explosive hydrogen gas does not accumulate if the tube is dry, the chlorinator has a **flow detector**: 1) In **AstralPool / Sugar Valley**: it has a **gas sensor** (the little wire plugged into the upper screw of the cell glass); If the sand filter is very dirty (manometer in yellow/red zone), an air bubble remains above the glass that touches the sensor and cuts off; do a **Sand Filter Wash and Rinse**. 2) On **Zodiac / Hayward**: carry a **mechanical paddle (Flow Switch)** on a T of the pipe that will have jammed or cut its RJ12 telephone type cable.

βœ• Scenario B: No (Not Present)

Check that the skimmer, sump and return cocks are open and that the pump pre-filter basket is not full of leaves.

3. Step-by-Step Multimeter Testing Procedure (No Flow / Flujo / FL1)

  1. Safety Power Isolation: Disconnect the Clorador Salino (AstralPool / Zodiac / Hayward) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault No Flow / Flujo / FL1 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: The upper gas sensor of the cell makes contact through the water itself with the titanium body.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Clorador Salino (AstralPool / Zodiac / Hayward) Error No Flow / Flujo / FL1

πŸ”„ Clorador Salino (AstralPool / Zodiac / Hayward) No Flow / Flujo / FL1 Reset: Wash the filter with sand to recover flow and check the cell upper sensor cable (or flow vane).
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Clorador Salino Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Clorador Salino (AstralPool / Zodiac / Hayward) No Flow / Flujo / FL1?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Clorador Salino (AstralPool / Zodiac / Hayward) Error Code No Flow / Flujo / FL1

What does Clorador Salino (AstralPool / Zodiac / Hayward) error code No Flow / Flujo / FL1 mean?

Clorador Salino (AstralPool / Zodiac / Hayward) No Flow / Flujo / FL1: Alarm for lack of water flow ('No Flow' / 'Flow' / red flow LED) with the purifier pump on (Cloradores Salinos AstralPool (Sel Clear, Smart Next, Elite), Zodiac (Ei2, eXO iQ), Sugar Valley (Aquascenic / Oxilife) and Hayward Aquarite). Multimeter Specs: The upper gas sensor of the cell makes contact through the water itself with the titanium body.

How do I reset Clorador Salino (AstralPool / Zodiac / Hayward) fault code No Flow / Flujo / FL1?

Wash the filter with sand to recover flow and check the cell upper sensor cable (or flow vane).

What multimeter values should I check for Clorador Salino (AstralPool / Zodiac / Hayward) code No Flow / Flujo / FL1?

The upper gas sensor of the cell makes contact through the water itself with the titanium body