Clorador Salino (AstralPool / Zodiac / Hayward) Error Code No Flow / Flujo / FL1: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Clorador Salino (AstralPool / Zodiac / Hayward) No Flow / Flujo / FL1)
| Manufacturer / Brand | Clorador Salino (AstralPool / Zodiac / Hayward) |
|---|---|
| Error Code | No Flow / Flujo / FL1 |
| System / Category | Pools & Lawn Mowers |
| Compatible Models | Cloradores Salinos AstralPool (Sel Clear, Smart Next, Elite), Zodiac (Ei2, eXO iQ), Sugar Valley (Aquascenic / Oxilife) and Hayward Aquarite |
| Severity Level | Low Severity · Maintenance Advisory |
| Multimeter Specs | The upper gas sensor of the cell makes contact through the water itself with the titanium body |
2. Guided Symptom Troubleshooting Matrix
For safety so that explosive hydrogen gas does not accumulate if the tube is dry, the chlorinator has a **flow detector**: 1) In **AstralPool / Sugar Valley**: it has a **gas sensor** (the little wire plugged into the upper screw of the cell glass); If the sand filter is very dirty (manometer in yellow/red zone), an air bubble remains above the glass that touches the sensor and cuts off; do a **Sand Filter Wash and Rinse**. 2) On **Zodiac / Hayward**: carry a **mechanical paddle (Flow Switch)** on a T of the pipe that will have jammed or cut its RJ12 telephone type cable.
Check that the skimmer, sump and return cocks are open and that the pump pre-filter basket is not full of leaves.
3. Step-by-Step Multimeter Testing Procedure (No Flow / Flujo / FL1)
- Safety Power Isolation: Disconnect the Clorador Salino (AstralPool / Zodiac / Hayward) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault No Flow / Flujo / FL1 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: The upper gas sensor of the cell makes contact through the water itself with the titanium body.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Clorador Salino (AstralPool / Zodiac / Hayward) Error No Flow / Flujo / FL1
Check OEM & aftermarket availability for Clorador Salino Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Clorador Salino (AstralPool / Zodiac / Hayward) Error Code No Flow / Flujo / FL1
What does Clorador Salino (AstralPool / Zodiac / Hayward) error code No Flow / Flujo / FL1 mean?
Clorador Salino (AstralPool / Zodiac / Hayward) No Flow / Flujo / FL1: Alarm for lack of water flow ('No Flow' / 'Flow' / red flow LED) with the purifier pump on (Cloradores Salinos AstralPool (Sel Clear, Smart Next, Elite), Zodiac (Ei2, eXO iQ), Sugar Valley (Aquascenic / Oxilife) and Hayward Aquarite). Multimeter Specs: The upper gas sensor of the cell makes contact through the water itself with the titanium body.
How do I reset Clorador Salino (AstralPool / Zodiac / Hayward) fault code No Flow / Flujo / FL1?
Wash the filter with sand to recover flow and check the cell upper sensor cable (or flow vane).
What multimeter values should I check for Clorador Salino (AstralPool / Zodiac / Hayward) code No Flow / Flujo / FL1?
The upper gas sensor of the cell makes contact through the water itself with the titanium body