BWT (Descalcificadores) Error Code El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (BWT (Descalcificadores) El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi))
| Manufacturer / Brand | BWT (Descalcificadores) |
|---|---|
| Error Code | El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi) |
| System / Category | Boilers & Heating |
| Compatible Models | Descalcificadores Domésticos BWT (Perla Silk, Aqa Perla, MyPerla, Rondomat, Belleza - Antes Cillit / ATH) |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Recommended output hardness after by-pass mixing in BWT softener: 5°fH to 8°fH (French grades) |
2. Guided Symptom Troubleshooting Matrix
Two breakdowns that occur in 99% of softeners when the salt does not go down: 1) **Salt Bridge (Hollow Vault)**: The salt tablets above have welded together with moisture forming a hard roof, but **below them is hollow and does not touch the water**, so the water does not have brine. **Test in 5 seconds**: Stick the handle of a clean broom downward through the salt until it touches the floor of the tank to break the vault. 2) **The Venturi Injector is clogged**: On the side of the upper head there is a small threaded cap; Inside it has a **plastic nozzle with a tiny hole (Venturi)** that creates a vacuum to suck the salt water. If it has a grittiness, it never sucks salt; Take it out with pliers, clean it with a pin and vinegar and launch a **Manual Regeneration (circular arrows button)**.
Break any caking salt vaults with a wooden strip, clean the head's Venturi injector and force a manual regeneration.
3. Step-by-Step Multimeter Testing Procedure (El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi))
- Safety Power Isolation: Disconnect the BWT (Descalcificadores) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Recommended output hardness after by-pass mixing in BWT softener: 5°fH to 8°fH (French grades).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear BWT (Descalcificadores) Error El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi)
Check OEM & aftermarket availability for BWT Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: BWT (Descalcificadores) Error Code El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi)
What does BWT (Descalcificadores) error code El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi) mean?
BWT (Descalcificadores) El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi): The BWT softener tank has been filled to the top with salt tablets for months, the salt level does not go down and the water at home has lime again (Descalcificadores Domésticos BWT (Perla Silk, Aqa Perla, MyPerla, Rondomat, Belleza - Antes Cillit / ATH)). Multimeter Specs: Recommended output hardness after by-pass mixing in BWT softener: 5°fH to 8°fH (French grades).
How do I reset BWT (Descalcificadores) fault code El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi)?
Dismantle and unclog the Venturi injector jet in the valve head and launch an immediate manual regeneration.
What multimeter values should I check for BWT (Descalcificadores) code El Water Sale Dura with Cal Aunque Hay Sal (Puente of Sal / Venturi)?
Recommended output hardness after by-pass mixing in BWT softener: 5°fH to 8°fH (French grades)