Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Electrodomésticos and Equipos Medium Severity · Protection Mode

boilers Error Code E160: Meaning, Multimeter Diagnosis & Fix

Fault code E160 on boilers units (All Series) indicates: Fault / Failure in el Fan of combustión: El Fan no alcanza el umbral of revoluciones consignado due to Fault / Failure in su Board / Plate integrada or Lockout / Blockage of the turbina. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Electrodomésticos and Equipos subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (boilers E160)

Manufacturer / Brandboilers
Error CodeE160
System / CategoryElectrodomésticos and Equipos
Compatible ModelsAll Series
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsPower supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does boilers error code E160 return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Fault / Failure in el Fan of combustión: El Fan no alcanza el umbral of revoluciones consignado due to Fault / Failure in su Board / Plate integrada or Lockout / Blockage of the turbina). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Desconectar of the red Electric 5 minutes, verify el componente with multímetro and ejecutar secuencia of reinicio.

3. Step-by-Step Multimeter Testing Procedure (E160)

  1. Safety Power Isolation: Disconnect the boilers unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E160 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear boilers Error E160

πŸ”„ boilers E160 Reset: Desconectar of the red Electric 5 minutes, verify el componente with multímetro and ejecutar secuencia of reinicio.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for boilers Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for boilers E160?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: boilers Error Code E160

What does boilers error code E160 mean?

boilers E160: Fault / Failure in el Fan of combustión: El Fan no alcanza el umbral of revoluciones consignado due to Fault / Failure in su Board / Plate integrada or Lockout / Blockage of the turbina (All Series). Multimeter Specs: Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital.

How do I reset boilers fault code E160?

Desconectar of the red Electric 5 minutes, verify el componente with multímetro and ejecutar secuencia of reinicio.

What multimeter values should I check for boilers code E160?

Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital