V2C Trydan Error Code El Coche No Inicia la Carga in Modo 'Excedentes Solares': Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (V2C Trydan El Coche No Inicia la Carga in Modo 'Excedentes Solares')
| Manufacturer / Brand | V2C Trydan |
|---|---|
| Error Code | El Coche No Inicia la Carga in Modo 'Excedentes Solares' |
| System / Category | Automotive OBD2 & EV |
| Compatible Models | Cargadores Inteligentes Españoles V2C Trydan (Monofásico 7.4 kW and Trifásico 22 kW - Control Dinámico e Integración Fotovoltaica) |
| Severity Level | Low Severity · Maintenance Advisory |
| Multimeter Specs | Minimum physical threshold to activate the charging contactor in Solar Surplus mode: > 1,380W sustained free (6A x 230V) |
2. Guided Symptom Troubleshooting Matrix
Mandatory technical rule for all electric cars (IEC 61851 Regulation)!: **No electric car on the market accepts charging at less than 6 Amps (which is 1,380W left over in single-phase, or 4,140W in three-phase)**. If your solar panels produce 2,000W but your house is spending 900W on the refrigerator and TV, you only have **1,100W of surplus left (< 6A)** and the charger waits so as not to suck from the payment network.
**Solution in the V2C Cloud app**: Change the solar mode to **'Surplus + Network (Min 6A)'** so that even if there is a lack of 200W of sun, it maintains continuous charging without cutting the contactor every time a cloud passes.
3. Step-by-Step Multimeter Testing Procedure (El Coche No Inicia la Carga in Modo 'Excedentes Solares')
- Capture OBD-II Freeze Frame Data: Record engine RPM, coolant temperature, and fuel trims stored when code El Coche No Inicia la Carga in Modo 'Excedentes Solares' triggered on your V2C Trydan.
- Harness & Connector Inspection: With ignition OFF, inspect the sensor/actuator plug for corroded pins, oil intrusion, or chafed insulation.
- Reference Voltage & Ground Drop Test: With ignition ON (engine off), use a digital multimeter to verify 5.0V / 12V supply and confirm ground voltage drop is below 0.05V.
- Component Specification Check: Measure internal resistance or signal output directly against factory specs: Minimum physical threshold to activate the charging contactor in Solar Surplus mode: > 1,380W sustained free (6A x 230V).
4. How to Reset & Clear V2C Trydan Error El Coche No Inicia la Carga in Modo 'Excedentes Solares'
Check OEM & aftermarket availability for V2C Trydan OBD2 Diagnostic Scanner:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: V2C Trydan Error Code El Coche No Inicia la Carga in Modo 'Excedentes Solares'
What does V2C Trydan error code El Coche No Inicia la Carga in Modo 'Excedentes Solares' mean?
V2C Trydan El Coche No Inicia la Carga in Modo 'Excedentes Solares': You have activated the Photovoltaic / Surplus mode on your V2C Trydan, it is sunny, but the electric car does not start charging (Cargadores Inteligentes Españoles V2C Trydan (Monofásico 7.4 kW and Trifásico 22 kW - Control Dinámico e Integración Fotovoltaica)). Multimeter Specs: Minimum physical threshold to activate the charging contactor in Solar Surplus mode: > 1,380W sustained free (6A x 230V).
How do I reset V2C Trydan fault code El Coche No Inicia la Carga in Modo 'Excedentes Solares'?
Activate the minimum network support option (6A) in the V2C Cloud app or wait for the net surplus to exceed 1,400W free.
What multimeter values should I check for V2C Trydan code El Coche No Inicia la Carga in Modo 'Excedentes Solares'?
Minimum physical threshold to activate the charging contactor in Solar Surplus mode: > 1,380W sustained free (6A x 230V)