Fault code E517H / W517H on Truma (Camper / Autocaravana) units (Calefacción and Water Caliente Truma Combi 4, Combi 6, Combi D (Diesel), Panel CP Plus iNet) indicates: Fault / Failure in el suministro of gas or bombona vacía / valve Crash Sensor disparada (Also E507H / E516H). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Automotive OBD2 & EV subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Truma (Camper / Autocaravana) E517H / W517H)

Manufacturer / BrandTruma (Camper / Autocaravana)
Error CodeE517H / W517H
System / CategoryAutomotive OBD2 & EV
Compatible ModelsCalefacción and Water Caliente Truma Combi 4, Combi 6, Combi D (Diesel), Panel CP Plus iNet
Severity LevelHigh Severity · Safety Lockout
Multimeter Specspressure regulador gas caravana: 30 mbar | Consumo startup Truma Combi: 12V DC (~1.8 A)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Truma (Camper / Autocaravana) error code E517H / W517H return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Fault / Failure in el suministro of gas or bombona vacía / valve Crash Sensor disparada (Also E507H / E516H)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: pressure regulador gas caravana: 30 mbar | Consumo startup Truma Combi: 12V DC (~1.8 A). If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Rearmar el Button of the Crash Sensor in el regulador of the bombona, purgar Air in los fogones and borrar el error pulsando el Button giratorio of the panel CP Plus (si esperas más of 15 min after 4 intentos, se desbloquea).

3. Step-by-Step Multimeter Testing Procedure (E517H / W517H)

  1. Capture OBD-II Freeze Frame Data: Record engine RPM, coolant temperature, and fuel trims stored when code E517H / W517H triggered on your Truma (Camper / Autocaravana).
  2. Harness & Connector Inspection: With ignition OFF, inspect the sensor/actuator plug for corroded pins, oil intrusion, or chafed insulation.
  3. Reference Voltage & Ground Drop Test: With ignition ON (engine off), use a digital multimeter to verify 5.0V / 12V supply and confirm ground voltage drop is below 0.05V.
  4. Component Specification Check: Measure internal resistance or signal output directly against factory specs: pressure regulador gas caravana: 30 mbar | Consumo startup Truma Combi: 12V DC (~1.8 A).

4. How to Reset & Clear Truma (Camper / Autocaravana) Error E517H / W517H

πŸ”„ Truma (Camper / Autocaravana) E517H / W517H Reset: Rearmar el Button of the Crash Sensor in el regulador of the bombona, purgar Air in los fogones and borrar el error pulsando el Button giratorio of the panel CP Plus (si esperas más of 15 min after 4 intentos, se desbloquea).
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (OBD2 Diagnostic Scanner)?

Check OEM & aftermarket availability for Truma OBD2 Diagnostic Scanner:

Want to use the interactive diagnostic wizard or electrical calculators for Truma (Camper / Autocaravana) E517H / W517H?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Truma (Camper / Autocaravana) Error Code E517H / W517H

What does Truma (Camper / Autocaravana) error code E517H / W517H mean?

Truma (Camper / Autocaravana) E517H / W517H: Fault / Failure in el suministro of gas or bombona vacía / valve Crash Sensor disparada (Also E507H / E516H) (Calefacción and Water Caliente Truma Combi 4, Combi 6, Combi D (Diesel), Panel CP Plus iNet). Multimeter Specs: pressure regulador gas caravana: 30 mbar | Consumo startup Truma Combi: 12V DC (~1.8 A).

How do I reset Truma (Camper / Autocaravana) fault code E517H / W517H?

Rearmar el Button of the Crash Sensor in el regulador of the bombona, purgar Air in los fogones and borrar el error pulsando el Button giratorio of the panel CP Plus (si esperas más of 15 min after 4 intentos, se desbloquea).

What multimeter values should I check for Truma (Camper / Autocaravana) code E517H / W517H?

pressure regulador gas caravana: 30 mbar | Consumo startup Truma Combi: 12V DC (~1.8 A)