Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Dishwashers Medium Severity · Protection Mode

Smeg Error Code E1: Meaning, Multimeter Diagnosis & Fix

Fault code E1 on Smeg units (ST, STA, LVS, Serie 50's Style, Built-in) indicates: Aquastop anti-flood safety system activado (Water detectada in la bandeja Lower of the Dishwasher). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Dishwashers subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Smeg E1)

Manufacturer / BrandSmeg
Error CodeE1
System / CategoryDishwashers
Compatible ModelsST, STA, LVS, Serie 50's Style, Built-in
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsMicrointerruptor boya Aquastop: open at rest (idle)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does Smeg error code E1 return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Aquastop anti-flood safety system activado (Water detectada in la bandeja Lower of the Dishwasher)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Microinterruptor boya Aquastop: open at rest (idle). If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Desenchufar, Empty / Drain el Water of the bandeja Lower and secar la zona of the flotador.

3. Step-by-Step Multimeter Testing Procedure (E1)

  1. Safety Power Isolation: Disconnect the Smeg unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault E1 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Microinterruptor boya Aquastop: open at rest (idle).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Smeg Error E1

πŸ”„ Smeg E1 Reset: Desenchufar, Empty / Drain el Water of the bandeja Lower and secar la zona of the flotador.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Solenoid Inlet Valve / Aquastop)?

Check OEM & aftermarket availability for Smeg Solenoid Inlet Valve / Aquastop:

Want to use the interactive diagnostic wizard or electrical calculators for Smeg E1?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Smeg Error Code E1

What does Smeg error code E1 mean?

Smeg E1: Aquastop anti-flood safety system activado (Water detectada in la bandeja Lower of the Dishwasher) (ST, STA, LVS, Serie 50's Style, Built-in). Multimeter Specs: Microinterruptor boya Aquastop: open at rest (idle).

How do I reset Smeg fault code E1?

Desenchufar, Empty / Drain el Water of the bandeja Lower and secar la zona of the flotador.

What multimeter values should I check for Smeg code E1?

Microinterruptor boya Aquastop: open at rest (idle)