SAI / UPS (APC / Salicru / Eaton) Error Code F02 / beep Fijo Continuo (overload / Relé): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (SAI / UPS (APC / Salicru / Eaton) F02 / beep Fijo Continuo (overload / Relé))
| Manufacturer / Brand | SAI / UPS (APC / Salicru / Eaton) |
|---|---|
| Error Code | F02 / beep Fijo Continuo (overload / Relé) |
| System / Category | Printers & Office |
| Compatible Models | Sistemas of Power supply Ininterrumpida APC Back-UPS / Smart-UPS, Salicru SPS One / SOHO+, Eaton, CyberPower |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Voltage at the terminals of a healthy floating UPS battery: 13.5V - 13.8V DC (If disconnected it measures < 10.5V DC, it has a connected vessel) |
2. Guided Symptom Troubleshooting Matrix
1) **If you have just turned on a laser printer, a heater or a powerful game on the PC**: you have exceeded the maximum watts of the UPS (**Overload / Overload**). NEVER plug a laser printer or a power strip with electrical appliances into the 'Battery Backup' sockets of a UPS (a laser printer produces peaks of 1,200W when heating the fuser and burns out the UPS relays)! Unplug the printer, turn off the UPS and press the **black/white button on the rear thermal breaker ('Circuit Breaker / Push to Reset')**. 2) If **F02** comes out even without having anything plugged in behind it: the internal battery is completely dead or shorted or the contacts of the inverter relay are stuck on the board.
Only connect the PC and monitor to outlets with battery backup, leaving the printer outside the UPS.
3. Step-by-Step Multimeter Testing Procedure (F02 / beep Fijo Continuo (overload / Relé))
- Safety Power Isolation: Disconnect the SAI / UPS (APC / Salicru / Eaton) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault F02 / beep Fijo Continuo (overload / Relé) for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Voltage at the terminals of a healthy floating UPS battery: 13.5V - 13.8V DC (If disconnected it measures < 10.5V DC, it has a connected vessel).
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear SAI / UPS (APC / Salicru / Eaton) Error F02 / beep Fijo Continuo (overload / Relé)
Check OEM & aftermarket availability for SAI Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: SAI / UPS (APC / Salicru / Eaton) Error Code F02 / beep Fijo Continuo (overload / Relé)
What does SAI / UPS (APC / Salicru / Eaton) error code F02 / beep Fijo Continuo (overload / Relé) mean?
SAI / UPS (APC / Salicru / Eaton) F02 / beep Fijo Continuo (overload / Relé): The UPS emits a long uninterrupted beep ('BIIIIIIIP') with red Overload light or displays error F02 on the APC screen (Sistemas of Power supply Ininterrumpida APC Back-UPS / Smart-UPS, Salicru SPS One / SOHO+, Eaton, CyberPower). Multimeter Specs: Voltage at the terminals of a healthy floating UPS battery: 13.5V - 13.8V DC (If disconnected it measures < 10.5V DC, it has a connected vessel).
How do I reset SAI / UPS (APC / Salicru / Eaton) fault code F02 / beep Fijo Continuo (overload / Relé)?
Disconnect high consumption equipment (laser printers), press the rear 'Reset / Circuit Breaker' button of the UPS and check the status of the 12V battery.
What multimeter values should I check for SAI / UPS (APC / Salicru / Eaton) code F02 / beep Fijo Continuo (overload / Relé)?
Voltage at the terminals of a healthy floating UPS battery: 13.5V - 13.8V DC (If disconnected it measures < 10.5V DC, it has a connected vessel)