Puertas Garaje (BFT / Came / Erreka) Error Code SUC / Amperstop / to a Mitad: Meaning, Multimeter Diagnosis & Fix

Fault code SUC / Amperstop / to a Mitad on Puertas Garaje (BFT / Came / Erreka) units (Motores Corredera and Batientes BFT (Deimos, Phobos, Thalia, Zara), Came (BX, ZBX7N), Erreka, Pujol) indicates: The sliding door starts to move but stops halfway and returns back on its own (Anti-crush sensitivity or hard guide). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Robot Vacuums & Smart Home subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Puertas Garaje (BFT / Came / Erreka) SUC / Amperstop / to a Mitad)

Manufacturer / BrandPuertas Garaje (BFT / Came / Erreka)
Error CodeSUC / Amperstop / to a Mitad
System / CategoryRobot Vacuums & Smart Home
Compatible ModelsMotores Corredera and Batientes BFT (Deimos, Phobos, Thalia, Zara), Came (BX, ZBX7N), Erreka, Pujol
Severity LevelMedium Severity · Protection Mode
Multimeter SpecsSliding door motor capacitor 230V: 8 µF to 16 µF (450V AC)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does the gate start to close and halfway through, it stops and opens again as if it had collided with something?
βœ“ Scenario A: Yes (Confirmed)

The engine consumption sensor (**Amperstop / D-Track in BFT**) notices that the door is hard and thinks it is trapping a person: 1) Unlock the engine with the **triangular key/clutch** and move the door by hand from end to end: are there stones or gravel on the iron track on the floor or a stuck wheel? 2) If it is a **230V AC** motor, the **white start capacitor (8 µF to 16 µF)** inside the housing has lost strength in winter and the motor cannot handle the weight of the blade.

βœ• Scenario B: No (Not Present)

Never grease the nylon/steel toothed rack where the pinion bites with consistent grease (the grease sticks to the wind sand and forms a hard sandpaper; clean it with a dry brush).

3. Step-by-Step Multimeter Testing Procedure (SUC / Amperstop / to a Mitad)

  1. Safety Power Isolation: Disconnect the Puertas Garaje (BFT / Came / Erreka) unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault SUC / Amperstop / to a Mitad for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Sliding door motor capacitor 230V: 8 µF to 16 µF (450V AC).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Puertas Garaje (BFT / Came / Erreka) Error SUC / Amperstop / to a Mitad

πŸ”„ Puertas Garaje (BFT / Came / Erreka) SUC / Amperstop / to a Mitad Reset: Sweep stones from the floor rail, check that the blade runs smoothly in manual mode and replace the motor capacitor if it has lost torque.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Motor Run Capacitor)?

Check OEM & aftermarket availability for Puertas Garaje Motor Run Capacitor:

Want to use the interactive diagnostic wizard or electrical calculators for Puertas Garaje (BFT / Came / Erreka) SUC / Amperstop / to a Mitad?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Puertas Garaje (BFT / Came / Erreka) Error Code SUC / Amperstop / to a Mitad

What does Puertas Garaje (BFT / Came / Erreka) error code SUC / Amperstop / to a Mitad mean?

Puertas Garaje (BFT / Came / Erreka) SUC / Amperstop / to a Mitad: The sliding door starts to move but stops halfway and returns back on its own (Anti-crush sensitivity or hard guide) (Motores Corredera and Batientes BFT (Deimos, Phobos, Thalia, Zara), Came (BX, ZBX7N), Erreka, Pujol). Multimeter Specs: Sliding door motor capacitor 230V: 8 µF to 16 µF (450V AC).

How do I reset Puertas Garaje (BFT / Came / Erreka) fault code SUC / Amperstop / to a Mitad?

Sweep stones from the floor rail, check that the blade runs smoothly in manual mode and replace the motor capacitor if it has lost torque.

What multimeter values should I check for Puertas Garaje (BFT / Came / Erreka) code SUC / Amperstop / to a Mitad?

Sliding door motor capacitor 230V: 8 µF to 16 µF (450V AC)