Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Automotive OBD2 & EV High Severity · Safety Lockout

NIU / Super Soco Error Code Error 191 / Error 99 (BMS Battery): Meaning, Multimeter Diagnosis & Fix

Fault code Error 191 / Error 99 (BMS Battery) on NIU / Super Soco units (Scooters and Motos Electric NIU NQi, MQi, UQi, Super Soco TC Max, CPx, CUx) indicates: Fault / Failure of communication RS485 with la Battery of litio (Error 191 / 30 in NIU and Error 99 / 98 in Super Soco). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Automotive OBD2 & EV subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (NIU / Super Soco Error 191 / Error 99 (BMS Battery))

Manufacturer / BrandNIU / Super Soco
Error CodeError 191 / Error 99 (BMS Battery)
System / CategoryAutomotive OBD2 & EV
Compatible ModelsScooters and Motos Electric NIU NQi, MQi, UQi, Super Soco TC Max, CPx, CUx
Severity LevelHigh Severity · Safety Lockout
Multimeter Specselectrical connector of Battery Chogori/Higo: 2 pines gruesos of potencia (60V/72V DC) + 4/6 pines finos of datos BMS RS485

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Does NIU / Super Soco error code Error 191 / Error 99 (BMS Battery) return immediately after a full power cycle even when main supply voltage is stable?
βœ“ Scenario A: Yes (Confirmed)

Permanent hardware or sensor circuit fault (Fault / Failure of communication RS485 with la Battery of litio (Error 191 / 30 in NIU and Error 99 / 98 in Super Soco)). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: electrical connector of Battery Chogori/Higo: 2 pines gruesos of potencia (60V/72V DC) + 4/6 pines finos of datos BMS RS485. If it reads open circuit (OL) or dead short, replace the faulty part.

βœ• Scenario B: No (Not Present)

Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Bajar el disyuntor bajo el asiento, clean and ajustar los pines finos of datos of the electrical connector of the Battery and volver a conectar.

3. Step-by-Step Multimeter Testing Procedure (Error 191 / Error 99 (BMS Battery))

  1. Capture OBD-II Freeze Frame Data: Record engine RPM, coolant temperature, and fuel trims stored when code Error 191 / Error 99 (BMS Battery) triggered on your NIU / Super Soco.
  2. Harness & Connector Inspection: With ignition OFF, inspect the sensor/actuator plug for corroded pins, oil intrusion, or chafed insulation.
  3. Reference Voltage & Ground Drop Test: With ignition ON (engine off), use a digital multimeter to verify 5.0V / 12V supply and confirm ground voltage drop is below 0.05V.
  4. Component Specification Check: Measure internal resistance or signal output directly against factory specs: electrical connector of Battery Chogori/Higo: 2 pines gruesos of potencia (60V/72V DC) + 4/6 pines finos of datos BMS RS485.

4. How to Reset & Clear NIU / Super Soco Error Error 191 / Error 99 (BMS Battery)

πŸ”„ NIU / Super Soco Error 191 / Error 99 (BMS Battery) Reset: Bajar el disyuntor bajo el asiento, clean and ajustar los pines finos of datos of the electrical connector of the Battery and volver a conectar.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (OBD2 Diagnostic Scanner)?

Check OEM & aftermarket availability for NIU OBD2 Diagnostic Scanner:

Want to use the interactive diagnostic wizard or electrical calculators for NIU / Super Soco Error 191 / Error 99 (BMS Battery)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: NIU / Super Soco Error Code Error 191 / Error 99 (BMS Battery)

What does NIU / Super Soco error code Error 191 / Error 99 (BMS Battery) mean?

NIU / Super Soco Error 191 / Error 99 (BMS Battery): Fault / Failure of communication RS485 with la Battery of litio (Error 191 / 30 in NIU and Error 99 / 98 in Super Soco) (Scooters and Motos Electric NIU NQi, MQi, UQi, Super Soco TC Max, CPx, CUx). Multimeter Specs: electrical connector of Battery Chogori/Higo: 2 pines gruesos of potencia (60V/72V DC) + 4/6 pines finos of datos BMS RS485.

How do I reset NIU / Super Soco fault code Error 191 / Error 99 (BMS Battery)?

Bajar el disyuntor bajo el asiento, clean and ajustar los pines finos of datos of the electrical connector of the Battery and volver a conectar.

What multimeter values should I check for NIU / Super Soco code Error 191 / Error 99 (BMS Battery)?

electrical connector of Battery Chogori/Higo: 2 pines gruesos of potencia (60V/72V DC) + 4/6 pines finos of datos BMS RS485