Hotpoint Error Code F08 / F03: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Hotpoint F08 / F03)
| Manufacturer / Brand | Hotpoint |
|---|---|
| Error Code | F08 / F03 |
| System / Category | Washing Machines |
| Compatible Models | Washing machines and Lavasecadoras Hotpoint-Ariston ActiveCare, Natis, Aqualtis, NLLCD, RDSG |
| Severity Level | High Severity · Safety Lockout |
| Multimeter Specs | Hotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C |
2. Guided Symptom Troubleshooting Matrix
The **electric resistance that heats the water** (located in the lower rear part of the tank) has a calcified sheath with a microscopic crack that diverts moisture to the ground, and the electronic board detects this leak by marking **F08**.
Disconnect the two Faston wires from the resistor and measure between one terminal of the resistor and its central ground screw on a Megaohm (MΩ) scale: if it gives any reading instead of infinity (OL), change the resistance (€15).
3. Step-by-Step Multimeter Testing Procedure (F08 / F03)
- Safety Power Isolation: Disconnect the Hotpoint unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault F08 / F03 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Hotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear Hotpoint Error F08 / F03
Check OEM & aftermarket availability for Hotpoint NTC Temperature Sensor:
⚡ Open in Interactive Simulator →
5. Frequently Asked Questions: Hotpoint Error Code F08 / F03
What does Hotpoint error code F08 / F03 mean?
Hotpoint F08 / F03: Heating resistor relay stuck or ground fault in the heating resistor (F08) or NTC probe open (F03) (Washing machines and Lavasecadoras Hotpoint-Ariston ActiveCare, Natis, Aqualtis, NLLCD, RDSG). Multimeter Specs: Hotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C.
How do I reset Hotpoint fault code F08 / F03?
Check ground insulation of the heating resistor (25-30 Ω between terminals, Infinite MΩ to ground) and NTC probe (20 kΩ at 25°C).
What multimeter values should I check for Hotpoint code F08 / F03?
Hotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C