Engineering Review: 2026-11-21 · SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Washing Machines High Severity · Safety Lockout

Hotpoint Error Code F08 / F03: Meaning, Multimeter Diagnosis & Fix

Fault code F08 / F03 on Hotpoint units (Washing machines and Lavasecadoras Hotpoint-Ariston ActiveCare, Natis, Aqualtis, NLLCD, RDSG) indicates: Heating resistor relay stuck or ground fault in the heating resistor (F08) or NTC probe open (F03). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Washing Machines subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Hotpoint F08 / F03)

Manufacturer / BrandHotpoint
Error CodeF08 / F03
System / CategoryWashing Machines
Compatible ModelsWashing machines and Lavasecadoras Hotpoint-Ariston ActiveCare, Natis, Aqualtis, NLLCD, RDSG
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsHotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C

2. Guided Symptom Troubleshooting Matrix

🔎 Does code F08 appear even when the washing machine is paused or when the wash is finished?
✓ Scenario A: Yes (Confirmed)

The **electric resistance that heats the water** (located in the lower rear part of the tank) has a calcified sheath with a microscopic crack that diverts moisture to the ground, and the electronic board detects this leak by marking **F08**.

✕ Scenario B: No (Not Present)

Disconnect the two Faston wires from the resistor and measure between one terminal of the resistor and its central ground screw on a Megaohm (MΩ) scale: if it gives any reading instead of infinity (OL), change the resistance (€15).

3. Step-by-Step Multimeter Testing Procedure (F08 / F03)

  1. Safety Power Isolation: Disconnect the Hotpoint unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault F08 / F03 for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ω) or supply voltage against the nominal reference: Hotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C.
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Hotpoint Error F08 / F03

🔄 Hotpoint F08 / F03 Reset: Check ground insulation of the heating resistor (25-30 Ω between terminals, Infinite MΩ to ground) and NTC probe (20 kΩ at 25°C).
🛠️ Compatible Replacement Parts & Tools
Need to replace the faulty component (NTC Temperature Sensor)?

Check OEM & aftermarket availability for Hotpoint NTC Temperature Sensor:

Want to use the interactive diagnostic wizard or electrical calculators for Hotpoint F08 / F03?
⚡ Open in Interactive Simulator →

5. Frequently Asked Questions: Hotpoint Error Code F08 / F03

What does Hotpoint error code F08 / F03 mean?

Hotpoint F08 / F03: Heating resistor relay stuck or ground fault in the heating resistor (F08) or NTC probe open (F03) (Washing machines and Lavasecadoras Hotpoint-Ariston ActiveCare, Natis, Aqualtis, NLLCD, RDSG). Multimeter Specs: Hotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C.

How do I reset Hotpoint fault code F08 / F03?

Check ground insulation of the heating resistor (25-30 Ω between terminals, Infinite MΩ to ground) and NTC probe (20 kΩ at 25°C).

What multimeter values should I check for Hotpoint code F08 / F03?

Hotpoint 1700W heating resistance: ~28 Ω | Integrated NTC probe: ~20 kΩ at 25°C