Dacia Error Code Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP): Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (Dacia Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP))
| Manufacturer / Brand | Dacia |
|---|---|
| Error Code | Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP) |
| System / Category | Automotive OBD2 & EV |
| Compatible Models | Dacia Sandero (I, II, III Stepway), Duster, Jogger, Lodgy, Dokker (Motores 1.0 TCe, 0.9 TCe, 1.5 dCi / Blue dCi and ECO-G 100 GLP) |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Dacia's Landi Renzo LPG system automatically switches to LPG when the engine coolant exceeds 35°C - 40°C |
2. Guided Symptom Troubleshooting Matrix
Two exact parts that fail due to oily paraffin from LPG gas in **1.0 TCe ECO-G engines (factory Landi Renzo system)**: 1) **The Pressure and Temperature Sensor of the LPG Injector Rail (Bosch/Continental or Landi Renzo sensor screwed with 1 screw at the end of the black gas rail above the engine)**: it fills with heavy oil from the gas and causes a pressure failure; Take it out (by closing or releasing pressure from the tube), **clean it with brake/contact cleaner spray** or change it in 5 minutes (~β¬24 on Amazon). 2) **The LPG Reducer/Vaporizer Solenoid Valve** has a paraffin-stuck plunger or you have driven more than 25,000 km without changing the **2 LPG filters (gas phase and liquid phase)**.
Change the gas phase LPG filter cartridge every 20,000 km (the cylindrical aluminum canister that goes in the rubber tube on top of the engine costs β¬9).
3. Step-by-Step Multimeter Testing Procedure (Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP))
- Capture OBD-II Freeze Frame Data: Record engine RPM, coolant temperature, and fuel trims stored when code Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP) triggered on your Dacia.
- Harness & Connector Inspection: With ignition OFF, inspect the sensor/actuator plug for corroded pins, oil intrusion, or chafed insulation.
- Reference Voltage & Ground Drop Test: With ignition ON (engine off), use a digital multimeter to verify 5.0V / 12V supply and confirm ground voltage drop is below 0.05V.
- Component Specification Check: Measure internal resistance or signal output directly against factory specs: Dacia's Landi Renzo LPG system automatically switches to LPG when the engine coolant exceeds 35°C - 40°C.
4. How to Reset & Clear Dacia Error Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP)
Check OEM & aftermarket availability for Dacia OBD2 Diagnostic Scanner:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: Dacia Error Code Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP)
What does Dacia error code Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP) mean?
Dacia Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP): Your LPG (ECO-G) Dacia Sandero, Duster or Jogger beeps and switches to gasoline only saying 'Check Injection / LPG not available' (Dacia Sandero (I, II, III Stepway), Duster, Jogger, Lodgy, Dokker (Motores 1.0 TCe, 0.9 TCe, 1.5 dCi / Blue dCi and ECO-G 100 GLP)). Multimeter Specs: Dacia's Landi Renzo LPG system automatically switches to LPG when the engine coolant exceeds 35°C - 40°C.
How do I reset Dacia fault code Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP)?
Clean or replace the pressure/temperature sensor at the end of the LPG injector rail and change the gas and liquid phase LPG filters.
What multimeter values should I check for Dacia code Fault / Failure Sistema GLP / No Pasa a Gas in Dacia ECO-G 100 (Sensor pressure Rampa GLP)?
Dacia's Landi Renzo LPG system automatically switches to LPG when the engine coolant exceeds 35°C - 40°C