Engineering Review: 2026-11-21 Β· SAE J2012 / IEC / OEM Verified
ESENDEFRIT
Camiones and Maquinaria High Severity · Safety Lockout

Caterpillar Error Code Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric): Meaning, Multimeter Diagnosis & Fix

Fault code Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric) on Caterpillar units (Excavadoras, Retrocargadoras (Mixtas 428, 432, 434), Minicargadoras and Palas Caterpillar (CAT 301, 305, 308, 320, 226B/D)) indicates: Your backhoe loader (mixed CAT 428 / 432) or excavator with a Perkins/CAT engine stalls when you use force with the bucket or has trouble starting in the mornings. The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Camiones and Maquinaria subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Caterpillar Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric))

Manufacturer / BrandCaterpillar
Error CodePérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric)
System / CategoryCamiones and Maquinaria
Compatible ModelsExcavadoras, Retrocargadoras (Mixtas 428, 432, 434), Minicargadoras and Palas Caterpillar (CAT 301, 305, 308, 320, 226B/D)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsCAT/Perkins electric primer pump power supply: 12V DC (in mixed 428/432) or 24V DC (in crawler excavators)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž When you put the bucket in the pile of dirt and ask the hydraulics for 100%, does the diesel engine choke and smoke or turn off?
βœ“ Scenario A: Yes (Confirmed)

In **CAT / Perkins (4.4L)** engines that have mixed and telescopic ones, on top of the diesel filter support there is an **Electric Primer Pump with a square black head (where the filter is screwed)**. When you turn on the ignition you have to hear its *'tic-tic-tic'* or hum filling the filter: 1) Unscrew with a wrench the small round cap on the head of that electric pump: inside it has a **tiny fine-mesh thimble filter that blocks 100% of the dregs from the diesel can**. 2) If the electric pump does not hum when the ignition is turned on, replace it completely (~€55 on Amazon).

βœ• Scenario B: No (Not Present)

Clean the internal microfilter of the electric priming pump head above the diesel filter.

3. Step-by-Step Multimeter Testing Procedure (Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric))

  1. Safety Power Isolation: Disconnect the Caterpillar unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
  2. PCB & Harness Terminal Check: Inspect the connectors associated with fault Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric) for moisture, scale buildup, loose pins, or heat discoloration.
  3. Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: CAT/Perkins electric primer pump power supply: 12V DC (in mixed 428/432) or 24V DC (in crawler excavators).
  4. Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.

4. How to Reset & Clear Caterpillar Error Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric)

πŸ”„ Caterpillar Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric) Reset: Verify that the electric transfer pump on the filter holder works when the ignition is turned on and clean its internal inlet screen.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (Replacement Sensor / Part)?

Check OEM & aftermarket availability for Caterpillar Replacement Sensor / Part:

Want to use the interactive diagnostic wizard or electrical calculators for Caterpillar Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric)?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Caterpillar Error Code Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric)

What does Caterpillar error code Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric) mean?

Caterpillar Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric): Your backhoe loader (mixed CAT 428 / 432) or excavator with a Perkins/CAT engine stalls when you use force with the bucket or has trouble starting in the mornings (Excavadoras, Retrocargadoras (Mixtas 428, 432, 434), Minicargadoras and Palas Caterpillar (CAT 301, 305, 308, 320, 226B/D)). Multimeter Specs: CAT/Perkins electric primer pump power supply: 12V DC (in mixed 428/432) or 24V DC (in crawler excavators).

How do I reset Caterpillar fault code Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric)?

Verify that the electric transfer pump on the filter holder works when the ignition is turned on and clean its internal inlet screen.

What multimeter values should I check for Caterpillar code Pérdida of Fuerza in Motor CAT / Perkins (Pump Cebadora Electric)?

CAT/Perkins electric primer pump power supply: 12V DC (in mixed 428/432) or 24V DC (in crawler excavators)