Carretilla Linde / Still Error Code T220 / T221 / No Anda: Meaning, Multimeter Diagnosis & Fix

Fault code T220 / T221 / No Anda on Carretilla Linde / Still units (Carretillas Elevadoras and Apiladores Electric Linde (E14, E16, E20, T16, T20, L12) and Still (RX20, RX60, EXU)) indicates: Incorrect starting sequence or fault in the accelerator pedal potentiometer / seat microswitch (Linde series 386 / 1152). The electronic control module triggers this diagnostic trouble code when sensor feedback or actuator response in the Automotive OBD2 & EV subsystem falls outside factory tolerances.

1. Technical Specifications & Multimeter Values (Carretilla Linde / Still T220 / T221 / No Anda)

Manufacturer / BrandCarretilla Linde / Still
Error CodeT220 / T221 / No Anda
System / CategoryAutomotive OBD2 & EV
Compatible ModelsCarretillas Elevadoras and Apiladores Electric Linde (E14, E16, E20, T16, T20, L12) and Still (RX20, RX60, EXU)
Severity LevelHigh Severity · Safety Lockout
Multimeter SpecsLinde accelerator potentiometer signal: Track 1 and Track 2 crossed (5V DC power supply)

2. Guided Symptom Troubleshooting Matrix

πŸ”Ž Do you start the Linde forklift, release the brake but it does not go forward or backward, displaying serial code T200 (T220 / T221)?
βœ“ Scenario A: Yes (Confirmed)

On Linde forklifts, if you turn on the ignition with your foot resting on the accelerator pedal or without sitting on the seat, the control unit blocks traction for safety: 1) **Lift both feet off the pedals**, sit well in the center of the seat (check that the 2-wire connector under the seat upholstery is not loose) and turn on the ignition again. 2) If **T220/T221** appears fixed: the **accelerator pedal double track potentiometer** is out of calibration or dirty with warehouse dust.

βœ• Scenario B: No (Not Present)

Also check that the red emergency stop button is turned and fully raised.

3. Step-by-Step Multimeter Testing Procedure (T220 / T221 / No Anda)

  1. Capture OBD-II Freeze Frame Data: Record engine RPM, coolant temperature, and fuel trims stored when code T220 / T221 / No Anda triggered on your Carretilla Linde / Still.
  2. Harness & Connector Inspection: With ignition OFF, inspect the sensor/actuator plug for corroded pins, oil intrusion, or chafed insulation.
  3. Reference Voltage & Ground Drop Test: With ignition ON (engine off), use a digital multimeter to verify 5.0V / 12V supply and confirm ground voltage drop is below 0.05V.
  4. Component Specification Check: Measure internal resistance or signal output directly against factory specs: Linde accelerator potentiometer signal: Track 1 and Track 2 crossed (5V DC power supply).

4. How to Reset & Clear Carretilla Linde / Still Error T220 / T221 / No Anda

πŸ”„ Carretilla Linde / Still T220 / T221 / No Anda Reset: Turn off the ignition, remove your feet from the pedals, sit on the seat and turn on, waiting 3 seconds before stepping.
πŸ› οΈ Compatible Replacement Parts & Tools
Need to replace the faulty component (OBD2 Diagnostic Scanner)?

Check OEM & aftermarket availability for Carretilla Linde OBD2 Diagnostic Scanner:

Want to use the interactive diagnostic wizard or electrical calculators for Carretilla Linde / Still T220 / T221 / No Anda?
⚑ Open in Interactive Simulator β†’

5. Frequently Asked Questions: Carretilla Linde / Still Error Code T220 / T221 / No Anda

What does Carretilla Linde / Still error code T220 / T221 / No Anda mean?

Carretilla Linde / Still T220 / T221 / No Anda: Incorrect starting sequence or fault in the accelerator pedal potentiometer / seat microswitch (Linde series 386 / 1152) (Carretillas Elevadoras and Apiladores Electric Linde (E14, E16, E20, T16, T20, L12) and Still (RX20, RX60, EXU)). Multimeter Specs: Linde accelerator potentiometer signal: Track 1 and Track 2 crossed (5V DC power supply).

How do I reset Carretilla Linde / Still fault code T220 / T221 / No Anda?

Turn off the ignition, remove your feet from the pedals, sit on the seat and turn on, waiting 3 seconds before stepping.

What multimeter values should I check for Carretilla Linde / Still code T220 / T221 / No Anda?

Linde accelerator potentiometer signal: Track 1 and Track 2 crossed (5V DC power supply)