bsh Error Code F42: Meaning, Multimeter Diagnosis & Fix
1. Technical Specifications & Multimeter Values (bsh F42)
| Manufacturer / Brand | bsh |
|---|---|
| Error Code | F42 |
| System / Category | Electrodomésticos and Equipos |
| Compatible Models | All Series |
| Severity Level | Medium Severity · Protection Mode |
| Multimeter Specs | Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital |
2. Guided Symptom Troubleshooting Matrix
Permanent hardware or sensor circuit fault (Subida brusca e incontrolada of revoluciones of the motor: Triac of potencia of the motor in short circuit in la main control board (PCB) or imán of the tacogenerador suelto in la cola of the motor). Disconnect the wiring harness and test the component with a digital multimeter against the factory specification: Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital. If it reads open circuit (OL) or dead short, replace the faulty part.
Intermittent safety lockout, oxidized connector pins, or temporary voltage dip. Clean the harness terminals, verify ground continuity, and execute the recommended reset procedure: Desconectar of the red Electric 5 minutes, verify el componente with multímetro and ejecutar secuencia of reinicio.
3. Step-by-Step Multimeter Testing Procedure (F42)
- Safety Power Isolation: Disconnect the bsh unit from mains power (230V / 120V AC) and wait at least 3 minutes for PCB capacitors to discharge before opening panels.
- PCB & Harness Terminal Check: Inspect the connectors associated with fault F42 for moisture, scale buildup, loose pins, or heat discoloration.
- Digital Multimeter Verification: Unplug the suspect sensor or actuator and measure its resistance (Ξ©) or supply voltage against the nominal reference: Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital.
- Reassembly & Cycle Validation: Once the out-of-spec component is cleaned or replaced, restore power and execute the reset sequence.
4. How to Reset & Clear bsh Error F42
Check OEM & aftermarket availability for bsh Replacement Sensor / Part:
β‘ Open in Interactive Simulator β
5. Frequently Asked Questions: bsh Error Code F42
What does bsh error code F42 mean?
bsh F42: Subida brusca e incontrolada of revoluciones of the motor: Triac of potencia of the motor in short circuit in la main control board (PCB) or imán of the tacogenerador suelto in la cola of the motor (All Series). Multimeter Specs: Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital.
How do I reset bsh fault code F42?
Desconectar of the red Electric 5 minutes, verify el componente with multímetro and ejecutar secuencia of reinicio.
What multimeter values should I check for bsh code F42?
Power supply nominal: 230V AC ±10% / Comprobación of continuidad and insulation with multímetro digital